Column Interaction Diagram (P-M Curve)

Generate the interaction diagram (P-M curve) for a concrete column according to ACI 318 and check if your axial load and bending moment are safe.

Column Parameters

Load Demands (Pu, Mu)

P1

Positive (+) for Compression, Negative (-) for Tension

Corner Reinforcement

336024941628761-105-97105099149198248MPP1

What is an Interaction Diagram?

An interaction diagram (or P-M curve) represents the combined axial load and bending moment capacity of a reinforced concrete column. Any combination of load and moment that falls inside the curve is considered safe according to ACI 318 standards.

Design Status

P1
Pu: 1200 | Mu: 150
UNSAFE

Reinforcement Ratio (ρ)

1.68 % (2011 mm²)