← Home

Footing Bearing Capacity Calculator

Design an isolated footing subjected to axial load and biaxial bending moments. Check soil pressures against allowable limits.

Footing & Load Parameters

Use service loads (unfactored) to check soil bearing pressures.

L = 2mB = 2m

What is Bearing Capacity Footing Design?

This calculator determines the maximum and minimum soil pressures under an isolated concrete footing subjected to axial load and biaxial bending moments. It verifies if the applied stresses comply with the allowable bearing capacity of the soil.

Engineering Formulas Used

The calculator uses the elastic flexural formula to determine the pressure at the corners. It also checks if the load eccentricity falls within the 'Kern' (middle third) to ensure the entire footing base is in compression.

q = (P / Area) ± (Mx * y / Ix) ± (My * x / Iy)

Biaxial Bending

When moments act on both the X and Y axes simultaneously, the pressure distribution becomes skewed. If the eccentricity e = M/P exceeds L/6 or B/6, uplift occurs, meaning a portion of the footing loses contact with the soil. ACI 318 recommends sizing the base area using service loads so that q_max ≤ q_allowable.

Design Status

UNSAFE

WARNING: Maximum pressure exceeds allowable soil bearing capacity.

Eccentricity e_x

0.050 m

Eccentricity e_y

0.075 m

Maximum Soil Pressure (q_max)

275.00 kPa

Minimum Soil Pressure (q_min)

125.00 kPa